loader from loading.io

TXV Troubleshooting - Short #245

HVAC School - For Techs, By Techs

Release Date: 06/17/2025

Maintenance Mindset - Short #249 show art Maintenance Mindset - Short #249

HVAC School - For Techs, By Techs

In this short podcast episode, Bryan explores the maintenance mindset. Maintenance procedures require a different skill set from troubleshooting, especially the customer service mindset and dedication to execution. Good maintenance is important, and it may be "boring" to some techs, but it provides value and is worth doing well. Clients purchase maintenance plans for better reliability and efficiency. Several also enjoy the health benefits of cleaner HVAC systems. The key to maintenance is having a "do no harm" mindset and a commitment to delivering value. A sales-oriented mindset should take...

info_outline
IAQ, Ethical Selling & Building Better Techs w/ Brynn Cooksey show art IAQ, Ethical Selling & Building Better Techs w/ Brynn Cooksey

HVAC School - For Techs, By Techs

In this episode of the HVAC School podcast, Bryan welcomes back Brynn Cooksey from Air Doctors and HVAC U to discuss critical topics facing the HVAC industry today. Brynn brings his unique perspective as both a successful contractor in southeast Michigan and an industry educator who has made the transition to focusing primarily on workforce development and training. The conversation begins with a deep dive into indoor air quality (IAQ), where Brynn challenges the common industry approach of throwing products at problems without proper testing. He emphasizes that effective IAQ solutions start...

info_outline
Crankcase Heaters - Short #248 show art Crankcase Heaters - Short #248

HVAC School - For Techs, By Techs

In this short podcast episode, Bryan talks about crankcase heaters, including their different types, what they do, and when we need to use them. Crankcase heaters usually come in belly band varieties, but some can be inserted into the sump of the compressor. As their name suggests, crankcase heaters heat the crankcase when the compressor is off. They prevent flooded starts since the heat keeps refrigerant from condensing to a liquid in the compressor when the system isn't running. Long off times, long line sets, and cold temperatures all increase a system's risk of flooded starts. Hard shutoff...

info_outline
The Contactor Reimagined w/ Copeland show art The Contactor Reimagined w/ Copeland

HVAC School - For Techs, By Techs

In this episode of the HVAC School podcast, Bryan welcomes back Jim to discuss the groundbreaking SureSwitch contactor technology from Copeland. This isn't just another incremental improvement - it's a complete reimagining of how contactors should work in modern HVAC systems. Jim brings his expertise and even demonstrates the technology with a special cutaway camera setup, giving listeners and viewers an inside look at this innovative solution. The conversation begins with the evolution of contactors in the HVAC industry, explaining how manufacturers moved backward from heavy-duty two-pole...

info_outline
Capacitor Testing and Replacement - Short #247 show art Capacitor Testing and Replacement - Short #247

HVAC School - For Techs, By Techs

In this short podcast episode, Bryan goes through the process of testing and replacing a run capacitor.  Run capacitors provide continuous phase-shifted current to the start winding, allowing the motor to run in the right direction and with the appropriate amount of torque. These capacitors are needed in most of the single-phase PSC motors we work with. Run capacitors are in the circuit all the time and are connected in series with the start winding (compared to start capacitors, which need to be taken out of the circuit after startup). They don't actually "boost" voltage. The bigger...

info_outline
Cold Coil vs. Desiccant Dehumidification show art Cold Coil vs. Desiccant Dehumidification

HVAC School - For Techs, By Techs

In this comprehensive episode of the HVAC podcast, Bryan hosts an in-depth discussion about dehumidification technologies with two industry experts: David Schurk, National Sales Manager for Innovative Air Technologies, and Nikki Krueger from Santa Fe Products. The conversation explores the fundamental differences between compression refrigeration dehumidification and solid desiccant systems, providing valuable insights for HVAC professionals dealing with moisture control challenges. David Schurk brings 44 years of industry experience and serves as an ASHRAE Life Member and Distinguished...

info_outline
Learning Better - Short #246 show art Learning Better - Short #246

HVAC School - For Techs, By Techs

In this short podcast episode, Bryan talks about learning styles and gives some tips for "learning better" and getting more out of continuing education opportunities. The first step to getting more out of educational opportunities is to know your learning style. There are three main styles: visual, kinesthetic (hands-on), and auditory. Most tradespeople will probably fall into the kinesthetic category, but not everybody is; you need to figure out if you're most comfortable working with your hands, listening to podcasts, watching videos, or reading. It's also a good idea to try the practical...

info_outline
Intro to The Sigma Capacitor show art Intro to The Sigma Capacitor

HVAC School - For Techs, By Techs

Sharon Goepferich from Cool Air Products joins the podcast to discuss cutting-edge capacitor technology and innovative HVAC solutions in an introduction to the Sigma capacitor. Sharon brings a decade of industry experience, having worked extensively with capacitors and HVAC components while traveling across the country to educate technicians and contractors. The conversation begins with a comprehensive breakdown of capacitor failures, addressing common misconceptions in the field. While manufacturing quality certainly plays a role in capacitor longevity, environmental factors like high...

info_outline
What's up with Refrigerant & System Regulations w/ Copeland show art What's up with Refrigerant & System Regulations w/ Copeland

HVAC School - For Techs, By Techs

In this insightful episode of the HVAC School podcast, host Bryan sits down with Jennifer Butsch, Director of Regulatory Affairs at Copeland, to discuss the rapidly evolving regulatory environment affecting the HVAC industry. With eight years of experience at Copeland and a background spanning codes, standards, and regulatory affairs, Jennifer provides a unique perspective on the challenges and opportunities facing contractors, technicians, and manufacturers in today's market. The conversation begins with an in-depth look at the EPA's Technology Transition Rule and the recent shift from...

info_outline
TXV Troubleshooting - Short #245 show art TXV Troubleshooting - Short #245

HVAC School - For Techs, By Techs

In this short podcast episode, Bryan walks through some common thermostatic expansion valve (TXV) troubleshooting scenarios. Many of the same principles apply to troubleshooting electronic expansion valves (EEVs). These dynamic metering devices maintain a constant superheat. Troubleshooting does NOT start and end with the TXV. First, you need to inspect components (especially filters, ductwork, and filter-driers) and confirm the airflow and charge. You can use measureQuick to monitor superheat, subcooling, static pressure, and other key measurements, and the TrueFlow grid can give you a true...

info_outline
 
More Episodes

In this short podcast episode, Bryan walks through some common thermostatic expansion valve (TXV) troubleshooting scenarios. Many of the same principles apply to troubleshooting electronic expansion valves (EEVs). These dynamic metering devices maintain a constant superheat.

Troubleshooting does NOT start and end with the TXV. First, you need to inspect components (especially filters, ductwork, and filter-driers) and confirm the airflow and charge. You can use measureQuick to monitor superheat, subcooling, static pressure, and other key measurements, and the TrueFlow grid can give you a true idea of the CFM your system is moving. Keep in mind that superheat and subcooling values can vary by system.

Airflow problems and filter-drier restrictions may mimic failed TXV conditions. Ideally, the liquid line filter-drier will be located indoors, and you can check for a pressure drop across it by looking for temperature differentials. You need a full column of liquid going into the filter-drier, and you can use a thermal imaging camera to see the desuperheating, condensing, and subcooling phases inside the condenser coil.

The TXV has a bulb that can be loose, improperly mounted, or improperly insulated; when there is an issue with the bulb, there will likely be low superheat. The bulb should be on a clean and [ideally] horizontal portion of the suction line, and it should be strapped with copper or stainless steel straps. Insulating the bulb is especially important when it's externally located and when low superheat or flood back is a concern. 

 

Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.

Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.

Subscribe to our podcast on your iPhone or Android.

Subscribe to our YouTube channel.

Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android