491 Environmental Microbiology and Legionella: Managing Building Water Risks with Dr. Rajiv Sahay
Release Date: 08/28/2026
Scaling UP! H2O
Strong professional associations do more than provide programs and credentials. They create an environment where members can exchange knowledge, build trusted relationships, and prepare their businesses for what comes next. As the Association of Water Technologies enters a new operational chapter, Executive Director explains how AWT is strengthening that environment without losing the culture that makes it distinctive. From the Arts to Association Leadership Before entering association management, Matt built a career behind the scenes in theater. His...
info_outlineScaling UP! H2O
Reliable Legionella results begin long before a sample reaches the laboratory. of explains how building conditions, field collection practices, and laboratory methods influence the quality—and usefulness—of the data water professionals receive. Building Water Conditions Shape the Risk Modern buildings rely heavily on controlled mechanical systems, yet water can remain an overlooked part of the indoor environment. Stagnation, low flow, dead legs, temperature, pH, disinfectant residuals, corrosion, and accumulated organic material can all influence biofilm development and microbial...
info_outlineScaling UP! H2O
A water management plan protects people only when the facility uses it to guide decisions. Dr. Abe Cullom, Director of Water Safety & Management at Pace Analytical, joins Trace Blackmore, CWT, to examine why Legionella programs break down—and how testing, communication, and consistent implementation can strengthen them. Implementation Is the Bottleneck Five decades after Legionella was identified, researchers understand much more about the organism, its ecology, the conditions that support its growth, and the interventions available to control it. However, Dr....
info_outlineScaling UP! H2O
Copper-silver ionization offers building operators a persistent approach to Legionella control—one designed to carry an active disinfectant residual throughout complex plumbing infrastructure. LiquiTech CEO Tory Schira explains how the technology works, what operating data matters, and why successful implementation requires more than installing equipment. How Copper-Silver Ionization Works Copper and silver ions are introduced through a flow chamber containing sacrificial electrodes. A controlled electrical charge releases the positively...
info_outlineScaling UP! H2O
“Our goal is not zero Legionella pneumophila bacteria. Our goal is zero cases.” – Patsy Root Legionella risk becomes harder to manage when building teams treat every detection as equivalent—or collect samples without first deciding what a positive result will trigger. , Senior Manager of Government Affairs at , explains how a clear water management program can replace uncertainty with defined responsibilities, routine monitoring, and proportionate action. Focus Testing on the Organism of Concern Patsy distinguishes between the broader...
info_outlineScaling UP! H2O
“Our gross profit margin is truly the battle we have to win in order to win all of the downstream wars.” - Tracy Bech Financial statements become useful when leaders can translate the numbers into decisions. , founder and author of , explains how business owners, managers, salespeople, and field professionals can develop financial fluency without becoming accountants. Turn Financial Data into a Meaningful Scorecard Tracy teaches finance through stories and relationships rather than isolated numbers. Revenue alone does not reveal whether a company is...
info_outlineScaling UP! H2O
Water meters register the volume passing through them, but what happens when that volume contains both water and entrained air? Anthony Giudice, president of AquaFlow, explains how turbulent flow can influence meter readings and how AquaFlow’s calibrated valve is designed to help meters reflect what he describes as true water consumption. Why Flow Conditions Matter at the Meter Anthony connects entrained air to the pressure required to move municipal water and the turbulence created as water travels through piping, changes...
info_outlineScaling UP! H2O
Ten questions from water professionals around the world become a practical decision-making session with Trace Blackmore, CWT. Drawing on earlier Scaling UP! H2O conversations, Trace explains how to evaluate treatment changes, use emerging tools responsibly, begin water reuse projects, strengthen teams, and continue growing professionally. Evaluate the Entire System A proposed treatment change should be evaluated by more than its purchase price. When comparing chlorine dioxide with traditional chlorine, Trace recommends examining biocide consumption, chemical storage,...
info_outlineScaling UP! H2O
Industrial operations depend on water of a predictable quantity and quality, yet many organizations still treat that reliability as a given. joins Trace Blackmore, CWT, to examine water security as a business continuity issue and resilience as the ability to withstand pressure, maintain operations, and recover quickly when systems fail. Connecting Risk, Resilience, and Recovery For industrial water users, water security means maintaining access to the quantity and quality required to operate without interruption. That reliability depends on...
info_outlineScaling UP! H2O
Industrial water professionals understand flow, pressure, heat exchange, wastewater, boilers, condensers, and process control. Alicia Butler-Pierre brings that same engineering logic into business systems, showing how work, information, decisions, and people move through an organization. Alicia, CEO of Equilibria, joins Trace Blackmore, CWT, to connect process engineering, operations management, Lean Six Sigma, dashboards, professional training, and business infrastructure. Her message is clear: whether you are moving water through a pipeline or work through a company, the question remains the...
info_outline
Reliable Legionella results begin long before a sample reaches the laboratory. Dr. Rajiv Sahay of Sahay Scientific Services explains how building conditions, field collection practices, and laboratory methods influence the quality—and usefulness—of the data water professionals receive.
Building Water Conditions Shape the Risk
Modern buildings rely heavily on controlled mechanical systems, yet water can remain an overlooked part of the indoor environment. Stagnation, low flow, dead legs, temperature, pH, disinfectant residuals, corrosion, and accumulated organic material can all influence biofilm development and microbial activity.
Dr. Sahay cautions against solving one problem while creating another. Raising a disinfectant concentration without considering system materials, water chemistry, and occupant health can introduce secondary risks. Instead, water professionals need enough data to balance microbial control with the operational realities of the system.
Better Samples Begin in the Field
Sample quality depends on what happens at the collection point. Dr. Sahay recommends recording temperature and pH when the sample is taken, selecting a collection technique suited to the water body, and avoiding unnecessary sediment or debris.
He also explains how gloves, hands, bottles, and sampling equipment can introduce cross-contamination. Aseptic handling, clean barriers, appropriate disinfection, and complete chain-of-custody documentation help the laboratory connect its findings with actual field conditions.
What Happens Inside the Laboratory
Dr. Sahay walks listeners through three testing pathways: non-culture methods, traditional culture, and molecular diagnostics such as PCR. Culture remains the reference method discussed for isolating and confirming Legionella, while molecular testing can provide faster screening information.
The conversation also follows a sample through filtration, preparation, inoculation on BCYE media, incubation, preliminary identification, and confirmation. This context helps water professionals understand why laboratory turnaround times and reported results vary by method.
Reading Results With the Right Context
A nondetect does not necessarily establish that an entire water system—or even the full sample bottle—contains no Legionella. It means the laboratory did not detect the organism in the analyzed portion under the method’s detection capability.
That distinction reinforces the central lesson: usable field data, representative sampling, appropriate laboratory methods, and informed interpretation must work together.
Listen to the full conversation above. Explore related episodes below. Stay engaged, keep learning, and continue scaling up your knowledge!
Connect with Dr. Rajiv Sahay
Phone: (727) 488-4001
Email: rajiv_sahay9@hotmail.com
Website: Environmental Services Consulting
LinkedIn: Dr. Rajiv Sahay, FIAS, CIAQP | LinkedIn
Sahay's Scientific Services: Overview | LinkedIn
Guest Resources Mentioned
CDC Legionella water management program overview
CDC Legionella prevention resources: https://www.cdc.gov/legionella/index.html
CDC ELITE Program (Environmental Legionella Isolation Techniques Evaluation)
EPA (Legionella-related publications and resources)
ASHRAE Standard 188 (Legionellosis risk management)
Scaling UP! H2O Resources Mentioned
AWT (Association of Water Technologies)
Scaling UP! H2O Academy video courses
Scaling UP! H2O Legionella Resources Library
Water You Know with James McDonald
Today's definition is an organophosphorus compound containing a direct carbon-phosphorus bond that is commonly used in water treatment for corrosion control and threshold scale inhibition. Can you guess the word or phrase?
2026 Events for Water Professionals
Check out our Scaling UP! H2O Events Calendar where we’ve listed every event Water Treaters should be aware of by clicking HERE.
This episode made possible through our valued partners at: